Velomitor CT Velocity Transducer

مشخصات فنی

Specification

Brand Name

Bently Nevada

A: Mounting Hardware Option
10 Plate Stud M6x1 to M6x1with 3/8-in 24 adapter
B: Connection Option
00 MIL-C-5015 connection interface
C: Agency Approval Option
00 No Approvals
Output Bias Voltage: 10.1 Vdc ± 1.0 Vdc
Dynamic Output Impedance: <400 Ω typical
Operating Temperature: -40°C to +85°C (-40°F to +185°F)
Storage Temperature: -40°C to +100°C (-40°F to +212°F)
Shock Limit: 5000 g pk, maximum
Humidity Limit: 100% condensing, non-submerged

Model Number

190501-10-00-00

Alternate Part Number

190501-10-00-00

Condition

100% Original

Dimensions

9.2x3.6x3cm

Description

Velomitor CT Velocity Transducer

Weight

0.03 kg

Warranty

12 Months

Product Description:

The 190501-10-00-00 Velomitor CT Velocity Transducer is a low-frequency version of our standard Velomitor Piezo-velocity Sensor. Its design specifically measures casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that operate at or above 90 rpm (100 to 300 rpm typical). The Velomitor CT Transducer can measure vibration amplitudes at these frequencies as well as the vibration frequencies generated by the fan motor and speed reducer.


Frequently Asked Questions (FAQ):
1.
What connection interface does the Bently Nevada 190501-10-00-00 use?

It uses a MIL-C-5015 industrial connection interface.


2.What is the output bias voltage of the Bently Nevada 190501-10-00-00?
The output bias voltage is 10.1 Vdc ± 1.0 Vdc.


3.What is the dynamic output impedance of the Bently Nevada 190501-10-00-00?
The dynamic output impedance is typically less than 400 Ω.

4.What is the shock limit of the Bently Nevada 190501-10-00-00?

The shock limit is 5000 g peak maximum.

5.What is the main function of the Bently Nevada 190501-10-00-00?

It measures vibration velocity in rotating machinery.

Application:

Petroleum, petrochemicals and refining: Air coolers of the units and cooling tower fans for process circulating water.
Electricity and energy: Cooling tower fans of thermal power plants and nuclear power plants, large-diameter low-speed circulating water pumps.
Chemical and fertilizer: Stirring machines, low-speed aeration machines, pumps and ventilation equipment in industrial wastewater treatment facilities.
Metallurgy and heavy manufacturing: Large low-speed axial flow fans, exhaust fans and mining equipment in steel mills.